vial adapter with filter Cuba

  • HIGHLIGHTS OF PRESCRIBING INFORMATION Children

     · • Filter the reconstituted product to remove potential particulate matter in the solution. Filtering is achieved by using the vial adapter. 1. Warm both unopened KOVALTRY vial and prefilled diluent syringe in your hands to a comfortable temperature (do not exceed 37°C or 99°F). 2. Remove the protective cap from the vial (A).

  • ICU Medical

    Number of Y-Sites. Product Image. . Multi-Dose Vial Adapter. 2" / 5.08 cm. . Two-Way Transfer Device.

  • Vial AdaptersWest Pharmaceutical Services

    Vial adapters are a cost-effective solution for the safe and rapid transfer and reconstitution of drugs between vials and syringes. Vial adapter spike technology provides a reproducible engineered depth. for drug and diluent aspiration, which greatly reduces the end-user variability associated with traditional needle aspirations and helps

  • Drug Preparation and Administration Catalog

     · CH-62 ChemoClave Vial Spike, 13 mm 50 ChemoClave Vented Vial Spikes A 0.22 micron hydrophobic filter automatically equalizes vial pressure. Allows access to vials with 13 mm, 20 mm, and 28 mm closures. Item Description Case Qty Product Image CH-70 ChemoClave Universal Vented Vial Spike, 20 mm and 28 mm 50 CH-70-5 ChemoClave Universal Vented

  • OnGuard® Vial Adaptor for 28 mm VialsBBraunUSA

     · OnGuard® Vial Adaptor. Benefits of OnGuard ® CSTD Majority of hazardous drug compounding can be done with just 3 SKU. Designed to reduce waste, help make implementations easier and reduce confusion. Just compound and go. No need to pre-prime or pre-activate the vial adaptor. Click to lock. No push and twist. Linear connection designed to

  • USB2Vented vial adapter with filter for aerosol

    A vented vial adapter has a filter attached to a vent arm that includes at least two filter media for suppressing aerosolized medicaments from leaving the vial and suppressing bacteria and other contaminants from entering the vial during reconstitution activities of the medication in the vial. The filter media allows the passage of air to the atmosphere outside the vial for pressure equalization.

  • ENFit Filtered Blunt NeedleNeoMed, Inc.

    Assembled with a protective sheath 5 µm filter for filling from glass ampules 18 gauge stainless steel needle with an angled tip allows for easy penetration through a vial’s rubber membrane 38 mm long for easy use with most vials Packaged sterile Commonly used with oral/enteral medications such as caffeine Features an ENFit connection, allowing ENFit syringe users to draw up oral/enteral

  • BD PhaSeal Optima System procedures

     · 5 Building a vial assembly using an assembly fixture (M12-O) Equipment necessary 1. BD PhaSeal™ Optima Protector according to neck size of the vial 2. BD PhaSeal™ Optima assembly fixture (M12-O) 3. Drug vial(s) 1 Place the assembly fixture on the work surface. 2 Remove the vial cap and disinfect per facility protocol. Place the vial on the assembly fixture

  • Mini-Spike®, Mini-Spike® V, Mini-Spike® Micro-tip

     · The range of green Mini-Spike® are used to withdraw or inject fluids from medication vial or semi-rigid containers. Featured with a 0,45µm bacteria retentive air filter

  • Use of Vial Adapters Can Reduce Drug Overfill

    Use of the Vial Adapter gave better consistency. The standard deviation for a 2 mL withdrawal was substantially lower with the Vial Adapter for all groups (see the table). From this it can be judged that delivery volume to the patient will likewise be more consistentand with better volume of delivery, it follows that the amount of overfill

  • EQUASHIELD Closed System Drug Transfer Device

     · Superior Safety and Ease of Use Introducing the 2nd generation of EQUASHIELD® Closed System Drug Transfer Device Covers more routes of exposure than alternative systems • The only system that prevents syringe plunger contamination (repeatedly identified as a major route of exposure to hazardous drugs).

  • Shop Vial AdapterMcKesson Medical-Surgical

    Call Us. Medical professionals, medical facility employees 855.571.2100. Need help with SupplyManager? 800.422.0280. Accounts Receivable 800.453.5180

  • West Reconstitution And Transfer SystemsWest 13 mm

    West 13 mm Swabable Vial Adapter. Vial adapters are a cost-effective solution for the safe and rapid transfer and reconstitution of drugs between vials and syringes. Vial adapter spike technology provides a reproducible engineered depth.

  • Vented Vial Adapter 0.2μm vent filterHelapet Ltd.

    Helapet Vented Vial Adapters are a safe and easy-to-use solution for reconstitution of cytotoxics, antibiotics and other hazardous chemicals. A single-use needle-free device, Helapet Vented Vial Adapters can be securely fastened to any standard 13mm or 20mm diameter vial. The novel skirt design prevents the adapter from being detached once

  • VENTED VIAL ADAPTER WITH FILTER FOR AEROSOL

     · A vented vial adapter has a filter attached to a vent arm that includes a t least two filter media for suppressing aerosolized medicaments from leavin g the vial and suppressing bacteria and other contaminants from entering the vial during reconstitution activities of the medication in the vial.

  • Vented vial adapterMedimop Medical Projects Ltd.

     · Vented safe handling vial adapter June, 2010 Mosler et al. Syringe devices and methods for mixing and administering medication June, 2010 Tennican et al. D616984 Vial adapter having side windows June, 2010 Gilboa Method and apparatus for an improved luer fitting connection May, 2010 Burton et al. D616090

  • Shop I.V. Therapy AccessoriesMcKesson Medical-Surgical

    Universal Vial Adapter (1) Vacuum Bottle (1) Vial Access Adapter (1) Vial Access Cap Spike (1) Y-Site Connector (1) Zero Reflux IV Connector (1) Embolization Coil (9) Luer Lock Cap (7) Pressure Monitoring Line (7) Tamper Evident Luer Lock Cap (7) Channel Two Diluent Set (6) Sealed Lead Acid Battery Pack (6) Catheter Repair Kit (5) Inflation

  • FEIBA (Anti-Inhibitor Coagulant Complex)

     · insertion of the spike to the diluent vial. 8. Gently swirl (do not shake) the vial until FEIBA is completely dissolved. Make sure that FEIBA has been dissolved completely otherwise, active material will not pass through the device filter. The reconstituted solution should be inspected visually for particulate matter before administration.

  • Small vial adapter with vented, spike, View filter, Chi

    Small vial adapter with vented Material Filter (PALL) ABS PP (cap) Can help the medical staff avoid drug infection. (See in Pic 3) And we can glue Gen2 needleless connector on it. Or assemble the CA-016 on it. (See in Pic 2) Picture location

  • ICU Medical

    Vial Adapter with Clave™ — allows vial access (13-20 mm) with luer tips of syringes. Product Numbers List Number shop.icumed Number EDI Number Nominal Length 2" / 5.08 cm Tubing I.D. 0.090" Priming Capacity (Approximate)

  • TEVADAPTOR Closed Drug Reconstitution and Transfer

     · Vial Adaptor The Tevadaptor® portfolio contains 3 different vial adaptors which firmly connect onto any standard vial, with a cap dimension of 13 & 20 mm (ref. 1MG245548), 28 mm ( ref. 1MG245766) or 32 mm (ref. 1MG245769). Once connected to the Tevadaptor® Syringe Adaptor, it allows a safe drug transfer

  • VENTED VIAL ADAPTER WITH FILTER FOR AEROSOL

     · The filter media allows the passage of air to the atmosphere outside the vial for pressure equalization. In another aspect, a third filter medium is used in the vent of the adapter to allow gas to pass in either direction through it, but prevents bacteria and particulate matter in the atmosphere from reaching the second filter device.

  • Filtertek Brings New Vial Adapter to Market Filtertek

    Company News Filtertek Brings New Vial Adapter to Market. New product designed for various vent and liquid filter options. HEBRON, IL (January, 2006)Filtertek, a leading developer of new medical products for healthcare OEM's, now offers a new vial adapter and filtration component system to facilitate medication access, reconstitution and transfer.

  • Mix2Vial Transfer SetCSL Behring

     · 4 ®Open the Mix2Vial filter transfer set by peeling off the lid. Do not remove the transfer set from the blister package. 5 Place the Sterile Water for Injection vial on an even, clean surface and hold the vial tight. Take the transfer set together with the blister package and push the spike of the blue adapter end straight down through

  • Products Aseptic TechnologiesSafer & Easier Aseptic

    Scaling-up solutions for your aseptic fill&finish from R&D to commercial batches. Bring full cGMP compliance, smooth validation and cost of goods reduction to the fill & finish of your novel therapy, combining AT-Closed Vial ® and isolator technology by SKAN. SKAN production isolators for filling lines are used in many FDA-approved systems

  • Filtration of Glass Delamination Particles with West

    One variant of the vial adapter is integrated with a filter to address various types of particles. In the present study, the performance of the filter-integrated vial adapter is evaluated with respect to glass delamination particles. Silica particles of 0.5–10 μm are used to emulate glass delamination particles.