vial adapter with filter Tadzhikistan

  • Om SinghFood and Drug Administration

     · Vial Adapter Ø20mm are indicated for the transfer and mixing of drugs contained in vials. 6. Intended use Vial Adapter are intended for use in healthcare facilities or in-home environment by the patient or care-giver to aid and support prescribed treatment and therapy. 7. Technological Characteristics and Substantial Equivalence

  • Dispensing Pin, Vial Adapter, Needleless #YM020 (Yukon

    ViaLok Vented Vial Access Device • The ViaLok Vented Vial Access Device is designed with a 0.2 micron filter to allow for venting during fluid withdrawal. • 20 mm standard closure • Universal • Easy attachment and superior vial security • Integrated grip reduces user

  • JIVI Product Monograph-2017 template

     · JIVI (Antihemophilic Factor [Recombinant, B-domain deleted, PEGylated]) with Vial Adapter (with a 15 micrometer filter) is a needleless system that prevents needlestick injuries during reconstitution (see WARNINGS AND PRECAUTIONS, General). Infuse JIVI intravenously over a period of 1 to 15 minutes, depending on the total volume. Adapt

  • USB2Vented vial adapter with filter for aerosol

    A vented vial adapter has a filter attached to a vent arm that includes at least two filter media for suppressing aerosolized medicaments from leaving the vial and suppressing bacteria and other contaminants from entering the vial during reconstitution activities of the medication in the vial. The filter media allows the passage of air to the atmosphere outside the vial for pressure equalization.

  • Use of Vial Adapters Can Reduce Drug Overfill

    Use of the Vial Adapter gave better consistency. The standard deviation for a 2 mL withdrawal was substantially lower with the Vial Adapter for all groups (see the table). From this it can be judged that delivery volume to the patient will likewise be more consistentand with better volume of delivery, it follows that the amount of overfill

  • Filtration of Glass Delamination Particles with West

    One variant of the vial adapter is integrated with a filter to address various types of particles. In the present study, the performance of the filter-integrated vial adapter is evaluated with respect to glass delamination particles. Silica particles of 0.5–10 μm are used to emulate glass delamination particles.

  • Medical Device VIAL ADAPTER50641

    vial adapter50674 ch-7313mm vented vial spike with tritan dianaonco ¿universal spike closed vial, clave ®ch-80 universal locking vented spike vial, clave ®ch-74 transfer setap2 0086sw drill for chemotherapy with air filter drive cairel505 kit integra2990

  • OnGuard® Vial Adaptor for 20 mm and 13 mm Vials

     · For closed reconstitution and withdrawal of medications with most 20 mm and 13 mm vials (with vial converter ring provided) Majority of hazardous drug compounding can be done with just 3 SKU. Designed to reduce waste, help make implementations easier and reduce confusion. Just compound and go. No need to pre-prime or pre-activate the vial adaptor.

  • Shop I.V. Therapy AccessoriesMcKesson Medical-Surgical

    Universal Vial Adapter (1) Vacuum Bottle (1) Vial Access Adapter (1) Vial Access Cap Spike (1) Y-Site Connector (1) Zero Reflux IV Connector (1) Embolization Coil (9) Luer Lock Cap (7) Pressure Monitoring Line (7) Tamper Evident Luer Lock Cap (7) Channel Two Diluent Set (6) Sealed Lead Acid Battery Pack (6) Catheter Repair Kit (5) Inflation

  • ICU Medical

    Vial Adapter — with 0.22 micron vent and Clave™ connector. Product Numbers List Number shop.icumed Number EDI Number Filtered No Sterile Pack No Hand Pump No Backcheck Valve No Latex Information Natural rubber latex has not been used in the manufacture of this product Case Information Order Quantity 1 Case (50) Case Size 1 x 50 Cases per Tier 36 Cases per

  • Drug Preparation and Administration Catalog

     · CH-62 ChemoClave Vial Spike, 13 mm 50 ChemoClave Vented Vial Spikes A 0.22 micron hydrophobic filter automatically equalizes vial pressure. Allows access to vials with 13 mm, 20 mm, and 28 mm closures. Item Description Case Qty Product Image CH-70 ChemoClave Universal Vented Vial Spike, 20 mm and 28 mm 50 CH-70-5 ChemoClave Universal Vented

  • GETTING STARTED WITH JIVI

    Jivi ® is available with the Vial Adapter needleless reconstitution system, which contains 1 Vial Adapter, with built-in 15-micrometer filter 2.5-mL diluent in a 5-mL syringe 25-gauge butterfly needle

  • Vented vial adapterMedimop Medical Projects Ltd.

     · Vented safe handling vial adapter June, 2010 Mosler et al. Syringe devices and methods for mixing and administering medication June, 2010 Tennican et al. D616984 Vial adapter having side windows June, 2010 Gilboa Method and apparatus for an improved luer fitting connection May, 2010 Burton et al. D616090

  • SmartSite Vented Vial Access DeviceBD

    1. 2. 3. This device partners with the Texium™ closed male Luer to provide closed-system access to drug vials. SmartSite™ needle-free valve includes Needle-free access to multiple-use vials. 0.2 micron hydrophobic air-venting filter provides Neutralization of vial pressure, minimizing aerosols and surface contamination. Eases drug extraction.

  • Closed System Transfer Devices HD Resource

    The first successful CSTD was Phaseal, currently made by BD. When introduced in 1999, it was a revolutionary concept components added to the traditional vial and syringe successfully prevented the escape of droplets, vapors and aerosols. During compounding, the vial adapter forced vapors and aerosols into an external balloon. Transfer of the

  • NovoSeven 1 mg (50KIU) powder and solvent for solution

     · – 1 vial adapter, with an integrated particle filter with a pore size of 25 micrometer. Vial Type I glass vial closed with a chlorobutyl rubber stopper, covered with an aluminium cap. The closed vial is equipped with a polypropylene tamper-evident snap-off cap.

  • 1 INDICATIONS AND USAGE

     · 11. Withdraw solution into the syringe by holding the vial on end above the vial adapter and syringe (I) then draw the plunger rod out slowly and smoothly. Ensure that the entire content of the vial is drawn into the syringe. 12. With the plunger rod in place, remove the syringe from the vial adapter (the latter should remain attached to the vial).

  • Vialok® Vented Vial Access Devices Yukon Medical

     · Vented vial access devices can be used on a variety of vials. They feature a .2 micron filter that minimizes aerosols and surface contamination while neutralizing vial pressure. Non-vented vial access devices are a great choice for use on small, low volume vials. Vented vial access devices available in universal, 13mm, 20mm, and 28mm sizes.

  • Shop I.V. Therapy AccessoriesMcKesson Medical-Surgical

    Universal Vial Adapter (1) Vacuum Bottle (1) Vial Access Adapter (1) Vial Access Cap Spike (1) Y-Site Connector (1) Zero Reflux IV Connector (1) Embolization Coil (9) Luer Lock Cap (7) Pressure Monitoring Line (7) Tamper Evident Luer Lock Cap (7) Channel Two Diluent Set (6) Sealed Lead Acid Battery Pack (6) Catheter Repair Kit (5) Inflation

  • Mixing and Preparing Sandostatin® LAR®

    Remove the lid film of the vial adapter packaging, but do NOT remove the vial adapter from its packaging. Holding the vial adapter packaging, position the vial adapter on top of the vial and push it fully down so that it snaps in place, confirmed by an audible “click.” Lift the packaging off the vial adapter

  • Shop Vial AdapterMcKesson Medical-Surgical

    Call Us. Medical professionals, medical facility employees 855.571.2100. Need help with SupplyManager? 800.422.0280. Accounts Receivable 800.453.5180

  • DailyMedIXINITY (coagulation factor ix- recombinant kit

    With the other hand, hold the IXINITY vial tightly on a clean, flat surface. In a continuous motion, place the vial adapter over the IXINITY vial firmly push the filter spike of the vial adapter through the center of IXINITY vial’s rubber circle until the clear plastic cap snaps onto the IXINITY vial (See Figure E). Push the plunger down to

  • DEPARTMENT OF HEALTH & HUMAN SERVICES Public

     · The vial adapter body contains the dual lumen piercing spike and the second part of the device is an assembled 0.2 m hydrophobic air path filter ( 100% expanded PTFE membrane over Non-woven polyester membrane support ).

  • OnGuard® Vial Adaptor for 28 mm VialsBBraunUSA

     · OnGuard® Vial Adaptor. Benefits of OnGuard ® CSTD Majority of hazardous drug compounding can be done with just 3 SKU. Designed to reduce waste, help make implementations easier and reduce confusion. Just compound and go. No need to pre-prime or pre-activate the vial adaptor. Click to lock. No push and twist. Linear connection designed to

  • Mix2Vial Transfer SetCSL Behring

     · 4 ®Open the Mix2Vial filter transfer set by peeling off the lid. Do not remove the transfer set from the blister package. 5 Place the Sterile Water for Injection vial on an even, clean surface and hold the vial tight. Take the transfer set together with the blister package and push the spike of the blue adapter end straight down through

  • Route of Immediate Content Pack size name

    vial adapter with filter 1 venipuncture set)) (multipack) 2/2 MA (EU) number (Invented) name Strength Pharmaceutical Form Route of Administration Immediate Packaging Content (concentration) Pack size EU/1/18/1324/009 Jivi 2000 IU Powder and solvent for solution for